CIP stands for Cleaning in Place – the cleaning of closed systems without disassembly. Cleaning agents are circulated through pipes, tanks, and fittings. The process is standard in the food, beverage, and pharmaceutical industries because it is reproducible, automatable, and documentable.
Typical process
- pre-rinse with water: Product residues are removed
- Alkaline cleaning (usually sodium hydroxide, approx. 1–2%, 60–85 °C): dissolves organic residues, fats and proteins
- Rinse between rinses with water
- Acidic cleaning (e.g., nitric or phosphoric acid): removes mineral deposits, limescale, and beerstone.
- Rinse with water, depending on the application with process water or ultrapure water
- Optional Disinfection
The cleaning process is effective due to the interplay of four factors that can partially replace each other (Sinner's circle): temperature, chemistry, mechanics (flow) and time.
Constructive requirements
A system is only CIP-capable if it is designed for it. Key points:
- Turbulent flow on all product-contacting surfaces – a minimum flow velocity of around 1,5 to 2 m/s is usually assumed.
- No dead dreamsBranches and sagging ends must be limited, as they are not flowable.
- Complete emptying capability due to gradient
- Gapless connections: welded seams instead of threads or flanges with gaps
- Smooth surfaces: low roughness (often required: Ra ≤ 0,8 µm) makes adhesion and biofilm formation more difficult.
- Material resistance resistant to alkalis, acids and temperature changes – is common 1.4404
Demarcation: SIP
SIP ( Sterilization in Place ) goes beyond cleaning: the system is additionally sterilized, usually with saturated steam. SIP requires CIP – only parts that have been previously cleaned are sterilized. Systems requiring SIP must also be steam-tight and designed for the relevant temperatures and pressures.
Regulations
Design requirements for cleanable systems are described, among other things, in the guidelines of the EHEDG (European Hygienic Engineering & Design Group). Related regulations include the 3-A Sanitary Standards and, for the pharmaceutical sector, the GMP guidelines.